Measurement Functions
 
3M™ Dynatel™ Advanced Modular System 965AMS
RFL (Resistance Fault Locate)
Use RFL 
 to find the distance to a short or ground. 
Important Note: You must first use the Auto test  , or the 
Ohmmeter  , to determine the type of fault. 
1.  There are two types of hook-ups, Separate Pair and Single 
Pair. Separate Pair is more accurate, but it requires hooking 
up more wires. The “Good” wires can be any gauge and any 
length. As an example, the Good wires can be jumper wire. 
Separate Pair is recommended for applications where you 
have a short or ground in an aerial cable or a direct buried 
cable and you want to find the fault the first measurement. 
2.  Single Pair requires that the “Good” wire is the same gauge 
and length as the faulted wire. Single Pair is appropriate for 
situations where you are looking for the fault to be in the 
nearest pedestal.
3.  RFL has the ability to find the distance to a short or ground 
using a single section of cable or a section with multiple 
gauges. Select Single- or Multi-section for your situation.
RFL>Hook-Up
There are ten possible scenarios for connecting a 965AMS tester 
to use the RFL function:
Tip-Ground Separate Pair
GRN 
BLK 
YEL 
BLU 
Ground (Earth)
Ground (Earth)
Tip (A) 1/Fault
Tip (A) 1/Fault
Ring (B) 2/Good
Ring (B) 2/Good
Tip (A) 2/Good
Tip (A) 2/Good
Fault
Strap