Polar G600 User Manual

Page of 8
2
UK
To unlock the control panel:
1.
Press and hold the UP 
 and DOWN
 
 buttons simultaneously for 10 
seconds.
2.
Pon flashes on the display and the keyboard is unlocked.
Enter the Parameter Menu
1.
Unlock the control panel, if locked.
2.
Press and hold the SET
 
 button until ‘d1’ flashes on the display.
3.
Press the SET
 
 button repeatedly to scroll to the desired parameter 
(see below).
.
Manual Defrost
The appliance will automatically run a defrost cycle every six hours. 
To manually defrost the appliance:
1.
Press and hold the DEFROST 
 button for 5 seconds.
2.
The defrost cycle will start immediately and the Defrost LED illuminates. 
The defrost will last a maximum of 30 minutes.
3.
The next automatic defrost will start six hours after the manual defrost 
has finished.
Note: 
If a button is not pressed for 10 seconds while using the 
control panel it times out and reverts to standby mode.
When parameters are being set the Setpoint LED will flash on 
the display.
Parameter
Name
Description
Range
d1
Operating temperature
Set the operating temperature of the appliance
-2°C to 10°C
d2
Temperature 
Differential
The Temperature Differential is the allowed temperature difference above and below the 
operating temperature before the compressor starts/cuts off
0 to 20°C
d3
Temperature Range 
Set the minimum (d3) and maximum (d4) temperatures that the appliance can fluctuate 
between
-40°C
d4
95°C
d5
Compressor Activation 
Time Intervals 
Enter the minimum time interval between the compressor turning off after turning on.
0-999 seconds
d6
Maximum Temperature 
Differential Alarm
Set an alarm to sound if the temperature inside the appliance exceeds the set operating 
temperature by a specified amount
0°C-50°C
d7
Temperature 
Differential Alarm Delay Set a delay before the temperature differential alarm is triggered
0-99 minutes
d8
Defrost Cycle Time 
Intervals
Set the time between each defrost cycle
1-999 hours
d9
Maximum Defrost 
Duration
Set the maximum length of the defrost cycle
Note: The defrost duration can be overridden by parameter d10 (below), if the 
cut-off temperature is reached before the end of the defrost duration
0-999 minutes
d10
Defrost Cut-off 
Temperature 
Set the defrost cut-off temperature
-45°C to 50°C
d11
Additional Cut-off 
Defrost Period 
Set an additional amount of defrost time after the defrost cut-off point has been reached (if 
required)
0-99 minutes
d12
Delayed Actual 
Temperature Display
Set the length of time the inner temperature of the appliance (before defrost started) is 
displayed for after a defrost cycle has finished
0-99 minutes
d13
Compressor On/Off 
During Defrost 
Turn the Compressor On or Off during the defrost cycle
On (1) or Off (0)
d14
Evaporator Drying Time
Set the amount of time the compressor remains turned Off after a defrost cycle, reducing the 
amount of frost build up
0-99 minutes
=19
Temperature Offset
Should there be any variance between measured and actual temperature, the measured 
temperature can be offset to compensate
-20°C to 20°C
=22
Unit of Measurement
Set whether the temperature is displayed in Centigrade or Fahrenheit
Centigrade (0) or Fahrenheit (1)
=23
Compressor Operation 
During Probe Failure
Set whether the compressor runs or remains Off during a temperature probe failure
Compressor runs (1)
Remains Off until fault fixed (0) 
Runs intermittently with 
parameters =24 and =25 (2) 
=24
Compressor ‘On’ 
Duration
Set the length of time the compressor runs during a temperature probe failure
1-99 minutes
=25
Compressor ‘Off’ 
Duration
Set the length of time the compressor remains Off during a temperature probe failure
1-99 minutes
=34
Initial Defrost After 
Startup 
Set whether the appliance starts a defrost cycle 10 minutes after startup or after the time 
programmed in parameter d8 (Defrost Cycle Time Intervals)
Begins 10 minutes after startup 
(0) or when programmed (1)
=38
Minimum Temperature 
Alarm
Set the display to flash should the inner temperature of the appliance drop beyond a specified 
point from the programmed operating temperature
1°C to 50°C
Note: The cycle starts from the time the appliance is initially 
powered up.
Note: Starting a manual defrost also resets the automatic 
defrost timer.