Panasonic NR-BU303 User Manual

Page of 8
 The distance from the wall is installed
 
The top of the refrigerator and the ceiling at least 30 cm.
 
The wall and the back of the refrigerator at least 10 cm.
 
The side of the refrigerator and the wall at least 5 cm.
Area around installed
 Do not locate the refrigerator in a humid place as rust may form 
and may cause electric leakage.
 
Do not locate the refrigerator exposing to direct sunlight as the 
heat and sunlight will increase the temperature.
 
Do not block the openings on the circumstances of the refrigerator.
 
The refrigerator must be located in the place where there is good 
air circulation.
 
In case of placing the refrigerator on an uneven surface, adjust the 
adjuster bolt to make the refrigerator stands stably. 
Moving or shifting
Installation
  
5 cm 
  
 The refrigerator LED lamp, specially designed for this refrigerator, does not function on individual 
replacing. If you need replacement, please contact Panasonic Service Center.
 If there is no grounding wiring plug in refrigerator, it should be connected with grounding connection 
to prevent electrical hazard.
 When moving or shifting the refrigerator, remove ice tray, ice box, pan water evap etc. 
and check to be sure that there is no water in the refrigerator.
LED lamp and Grounding
For safety, the grounding connection should be done 
(For a refrigerator with plug (2-pin plug) without any grounding wire) 
 
The grounding connection will allow prevention of danger resulted from electricity leakage. 
The grounding connection can be performed in 2 ways as follows: 
1.
  In the case that the grounding receptacle having 
been prepared for the socket (plug socket), connect 
the grounding wire to the screw used for grounding 
connection at the bottom rear of the refrigerator (regarding 
the screw used for grounding connection, please notice 
the   symbol) as shown in the illustration 1.
2.
  In the case that the socket (plug socket) having not 
been provided with any grounding receptacle, connect 
the grounding wire to the screw at the bottom of the 
refrigerator, (as regards the screw used for grounding 
connection, please notice the   symbol).  And then 
connect the other end to the grounding rod as shown in 
the illustration 2.
Prohibited spots for grounding connection
 
Gas pipes and water supply pipes (dangers from electric shock or explosion).
 
The grounding wires of telephone cords and lightning rods (dangers from lighting).
Grounding
receptacle
Grounding
wire
Illustration for the 
grounding connection
1
2
4
NR-BU303_343-EN-RBD.indd   4