GE ZICP360S Leaflet

Page of 2
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
Listed by 
Underwriters 
Laboratories
Specification Created 7/06
110193
696Dia7
6"
Wall View
Electrical
Area
84-1/2" max
83-1/2" min 
Finished 
Opening
75" From
Floor to  Bottom 
of Electrical
Area
10"
5"
3 1/2"
5"
3 1/2"
Water Supply 
24" Cutout Depth
35-1/2"
Finished Width
2-5/16"
*Shipping height. The 
  refrigerator can be adjusted 
  to fit into a cutout that is 
  83-1/2" min. to 84-1/2" max. 
  height. Note that the top case 
  trim at the front is 1/2" higher 
  and will overlap upper cabinetry 
  or soffit. Use leveling legs 
  and wheels for a maximum 
  1" height adjustment.  
25-3/4" Case Depth
84"* from
floor to 
top frame 
35" Case Width
83-1/2"*
at Rear 
28-11/16"
36" Frame to 
Frame Width
Depth Including Handles
The Installation Space 
The finished cutout width must be 35-1/2".
Product Dimensions
Shipping Height: 
The refrigerator 
can be adjusted 
to fit into a cutout 
that is 83-1/2" min. 
to 84-1/2" max. 
height. The top case 
trim at the front 
is 1/2" higher and 
will overlap upper 
cabinetry or soffit. 
Use leveling legs 
and wheels for a 
maximum 1" height 
adjustment.
The cutout depth must be 24" 
The refrigerator will project forward, slightly beyond adjacent 
cabinetry, depending on your installation.
The cutout depth beneath a soffit 
When installed beneath a soffit, the soffit cannot exceed the 
24" installation depth shown. The top case trim overlaps the 
bottom of the soffit.
Electrical 
A 115V, 60Hz., 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit breaker 
is recommended. Install a properly grounded 3-prong 
electrical receptacle recessed into the back wall. Electrical 
must be located on rear wall as shown.
 
Note: GFI (ground fault interrupter) is not recommended.
Water Line 
The water line can enter the opening through the floor 
or back wall. Route GE SmartConnect
 Kit or 1/4" O.D. 
copper tubing between the cold water line and the water 
connection location at the front of the refrigerator. The 
tubing must be long enough to extend to the front of the 
refrigerator. The installation of an easily accessible shut-off 
valve in the water line is required.
605Dia20
25"
Min. to
Wall
130
°
130
° Door Swing
23-7/8"
Behind
Frame
36-3/4"
zicp_bf_ref_qs_art
90
°
90
° Door Swing
5" Min.
to Wall
Door Swing Clearances
The installation must allow for clearances to adjacent walls 
or cabinets. These refrigerators are equipped with a 2-
position door stop. The factory-set 130° door swing can be 
adjusted to 90° if clearance to adjacent cabinets or walls is 
restricted.
Allow 25" minimum clearances for a full 130° door swing. 
Allow 15" for pan removal. 
•  5" minimum clearance is required when the door swing is 
adjusted to 90°. If the 90° door stop position is used, pan 
access is maintained, but pan removal is restricted.
Dimensions and Installation Information (in Inches)
ZICP360S 
GE Monogram 36" Professional Style Built-In Bottom Freezer Refrigerator