Wa t e r   S u p p l y   R e q u i r e m e n t s
All installations must meet local plumbing code requirements.
The water shutoff should be located in the base cabinet on 
either side of the refrigerator or some other easily accessible 
area. The right-hand side is recommended. The access hole 
through the cabinet must be within 
¹⁄₂" (12.7 mm) of the rear 
wall.
NOTE: If the water shut off valve is in the back wall behind 
the refrigerator, it must be at an angle so that the tube is not 
kinked when the refrigerator is pushed into its final position.
If the water shutoff valve is not in the cabinets, the plumbing 
for the water line can come through the floor. A 
¹⁄₂" (12.7 mm) 
hole for plumbing should be drilled at least 6" (15.2 cm) from 
the right or left hand side cabinet or panel. On the floor, the 
hole should be no more than 1" (2.54 cm) away from the back 
wall. See “Connect the Water Supply.”
If additional tubing is needed, use copper tubing and check 
for leaks. Install the copper tubing only in areas where the 
household temperatures will remain above freezing.
Do not use a piercing-type or 
³⁄₁₆" (4.76 mm) saddle valve 
which reduces water flow and clogs more easily.
NOTE: Your refrigerator dealer has a kit available with a 
¹⁄₄" 
(6.35 mm) saddle-type shutoff valve, a union, and copper 
tubing. Before purchasing, make sure a saddle-type valve 
complies with your local plumbing codes. 
Water Pressure
A cold water supply with water pressure between 30 and 120 psi 
(207 and 827 kPa) is required to operate the water dispenser and 
ice maker. If you have questions about your water pressure, call a 
licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
refrigerator needs to be between 30 and 120 psi 
(207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If your refrigerator has a water filter cartridge, it may further 
reduce the water pressure when used in conjunction with a 
reverse osmosis system. Remove the water filter cartridge. 
If you have questions about your water pressure, call a licensed, 
qualified plumber.
INSTALLATION INSTRUCTIONS
U n p a c k   t h e   R e f r i g e ra t o r
IMPORTANT: 
Do not remove the protective film until the refrigerator is in its 
operating position.
All four leveling legs must contact the floor to support and 
stabilize the full weight of the refrigerator.
Keep the cardboard shipping piece or plywood under the 
refrigerator until it is installed in the operating position.
1. Remove and save the literature package and parts bag taped 
to the refrigerator door. Remove the four brackets (two on 
each side) that attach the shipping base to the refrigerator 
bottom. 
NOTE: Do not remove tape and door bracing until the 
refrigerator is in its final position. 
2. If necessary, reduce the tipping radius. See “Tipping Radius” 
for ceiling height requirements or “Reduce Tipping Radius” 
for step-by-step instructions.  If you do not need to reduce 
the tipping radius, proceed to “Move the Refrigerator into 
House.”
24"
(60.96 cm) min. 
1"
(2.54 cm) 
6"
(15.2 cm)
6"
(15.2 cm)
6"
(15.2 cm)
WARNING
Tip Over Hazard
Refrigerator is top heavy and tips easily when not 
completely installed. 
Keep doors taped closed until refrigerator is 
completely installed.
Use two or more people to move and install 
refrigerator.
Failure to do so can result in death or serious injury.