Traulsen TE Series/TU Series/TS Series User Manual

Page of 4
III.  Control Basics:
Customer Access
To adjust any of the control’s operating features, enter the customer access 
code.  Use the code 
0, A, 1 combined with the following: Press the SET 
button.   The display will read 
CUS (Customer Access).  Press the SET but-
ton.  The display will show three zeros with the left zero flashing, Press the 
SET button.  The display will show three zeros with the center zero flashing.  
Press the 
DOWN ARROW key to sequence through F, E, d, C, b, A, 9, 8, 
7,…etc.  When you reach A press 
SET.  The display will show zero, A, zero 
with the right zero flashing.  Press the 
UP ARROW key to sequence through 
1, 2, 3, 4, 5, 6, 7, 8, 9, A, b,…etc.   When you reach 1 press 
SET.  The 
display will read 
SP (Thermostat Set Point).  Press the SET button to view 
and again to exit.  You are now ready to adjust the control.  Listed below 
are the available parameters in the order they appear, using the down arrow 
key on the controller, you can use either the up or down arrow keys to scroll 
through the options.
  Thermostat Set Point   
  Defrost Lockout 3
 
Thermostat Set Point Differential
 
 
  Defrost Lockout 4
 
  Temperature Scale 
 
 
Dew Point Compensation Factor
 
Time (24-hour clock)   
 
  Room Temperature Offset
  Date (month-day-year)  
  Audible Alarm Style
 
  Daylight Savings 
 
  Cabinet Air Sensor Temp
  Start Manual Defrost   
 
  Evaporator Coil Sensor
  Defrost Lockout 1 
 
  Liquid Line Sensor
  Defrost Lockout 2 
Defrost Lockout Feature
Defrost lockouts will allow the you to prevent defrost cycles from occurring 
for two hours during a designated time. Up to four can be set for any 24-
hour period.  Each of the lockout parameters covers 6-hours of the 24-hour 
clock. Note: The 24-hour clock must be set for this feature to operate at the 
correct time of day.
DL1/OFF 
DL2/OFF 
DL3/OFF 
DL4/OFF
020 = 2:00 a.m.  080 = 8:00 a.m.  140 = 2:00 p.m.  200 = 8:00 p.m.
023 = 2:30 a.m.  083 = 8:30 a.m.  143 = 2:30 p.m.  203 = 8:30 p.m.
030 = 3:00 a.m.  090 = 9:00 a.m.  150 = 3:00 p.m.  210 = 9:00 p.m.
033 = 3:30 a.m.  093 = 9:30 a.m.  153 = 3:30 p.m.  213 = 9:30 p.m.
040 = 4:00 a.m.  100 = 10:00 a.m. 160 = 4:00 p.m.  220 = 10:00 p.m.
043 = 4:30 a.m.  103 = 10:30 a.m. 163 = 4:30 p.m.  223 = 10:30 p.m.
050 = 5:00 a.m.  110 = 11:00 a.m. 170 = 5:00 p.m.  230 = 11:00 p.m.
053 = 5:30 a.m.  113 = 11:30 a.m. 173 = 5:30 p.m.  233 = 11:30 p.m.
060 = 6:00 a.m.  120 = 12:00 p.m. 180 = 6:00 p.m.  240* = 12:00 a.m.
063 = 6:30 a.m.  123 = 12:30 p.m. 183 = 6:30 p.m.  243* = 12:30 a.m.
070 = 7:00 a.m.  130 = 1:00 p.m.  190 = 7:00 p.m.  010 = 1:00 a.m.
073 = 7:30 a.m.  133 = 1:30 p.m.  193 = 7:30 p.m.  013 = 1:30 a.m.
080 = 8:00 a.m.  140 = 2:00 p.m.  200 = 8:00 p.m.  020 = 2:00 a.m.
Defrost Lockout Feature (continued)
NOTE:  First Enter Customer Access (see section III.)
When  the control displays 
 Thermostat Set Point, press the down 
arrow key 
 
 until the control displays  
 
 
   or   
 
 .  Press the set button         .  The display will show 
  off.  
Press the arrow keys 
 
 to set the start time.  When the correct time is 
displayed, press the set button 
SET
 .  You can press the up or down arrow 
keys 
 
  to scroll to the next parameter or press the alarm cancel 
button to exit          or leave inactive for 30 seconds. 
Setting The Clock
The internal time clock must be set in order for the data storage memory to 
correctly log events and to allow any defrost lockout to occur at the correct 
time of day. If the clock is not set, the control assumes the time is 12 a.m. 
at the time power is supplied to the unit. The hours on a 24-hour time clock 
read the following way:
H01 = 1:00 a.m.  H07 = 7:00 a.m.  H13 = 1:00 p.m.  H19 = 7:00 p.m.
H02 = 2:00 a.m.  H08 = 8:00 a.m.  H14 = 2:00 p.m.  H20 = 8:00 p.m.
H03 = 3:00 a.m.  H09 = 9:00 a.m.  H15 = 3:00 p.m.  H21 = 9:00 p.m.
H04 = 4:00 a.m.  H10 = 10:00 a.m. H16 = 4:00 p.m.  H22 = 10:00 p.m.
H05 = 5:00 a.m.  H11 = 11:00 a.m. H17 = 5:00 p.m.  H23 = 11:00 p.m.
H06 = 6:00 a.m.  H12 = 12:00 p.m. H18 = 6:00 p.m.  H24 = 12:00 a.m.
NOTE:  First Enter Customer Access (see section III.)
When the control displays 
 Thermostat Set Point, press the down 
arrow key 
 
 until the control display reads 
 clock.  Press the 
Set button 
SET
  .  The display will show 
 Hours. The right two 
numbers will be flashing.  Use the arrow keys               to set the hour.  
When the correct hour is displayed, press the Set button 
SET
  .  The 
display will show 
 minutes.  The right two numbers will be flash-
ing.  Use the arrow keys 
 
  to set the minutes.  When the correct 
hour is displayed, press the Set button  
SET
  .  The display will then read 
  clock.  You can use the up or down arrow keys 
 
  to the 
next parameter or press the alarm cancel button 
  to exit or leave 
inactive for 30 seconds.
Hot Food Holding Cabinet Operation
Hot Food Holding Cabinets differ from refrigerators and freezers in that they 
do not typically operate 24/7, and that there is a much broader range of 
safe storage temperatures to choose from (135-180°F).  As a result these 
are regularly turned ON and OFF.  To facilitate this Traulsen includes an ON/
OFF button on their controls.  This also includes a convenient Temperature 
Recall Feature.  Upon being turned on each day, this automatically returns 
operation to the last previously set temperature. 
-2-