INSTALLATION /  OPERATION INSTRUCTIONS
4
4
To insure that your unit works properly from the 
first day, it must be installed properly.  We highly 
recommend a trained refrigeration mechanic and 
electrician install your 
True equipment.   The cost 
of a professional installation is money well spent.
Before you start to install your 
True unit, carefully 
inspect it for freight damage. If damage is discov-
ered, immediately file a claim with the delivery 
freight carrier.  
True is not responsible for damage incurred 
during shipment. 
OWNERSHIP
 Adjustable 
Wrench
  Phillips Head Screwdriver
 Level
REQUIRED TOOLS
Step 1
The following procedure is recommended for 
uncrating the unit:
A.  Remove the outer packaging, (cardboard and 
bubbles or styrofoam corners and clear plastic). 
Inspect for concealed damage. Again, immedi-
ately file a claim with the freight carrier if there 
is damage. 
B.  Move your unit as close to the final location as 
possible before removing the wooden skid.
C.  Remove all tape securing the doors to the cool-
er, and any foam blocks between doors.
D.  Remove any components (castors, floor racks, 
etc.) packaged inside the cabinet.
Note: Keys for coolers with door locks are 
located in warranty packets.
UNCRATING
INSTALLATION / OPERATION INSTRUCTIONS
REMOTE UNITS (This section applies to remotes 
only!)
•  Remote cabinets must be ordered as remote.   
 
We do not recommend converting for a standard  
self contained to remote system.
•  All remote cabinets must be hard wired.
•  No castors available.
•  All remote cabinets come standard using 404A  
 refrigerant.
•  All remote units come standard with expansion  
 
valve, liquid line solenoid, heated condensate  
 
pan, and defrost timer when applicable.
•    Contact True Technical Service for BTU         
 requirements.
•  No wiring necessary between cabinet and      
 condensing 
unit.
•  All remote condensing units purchased from   
 
True are 208/230 volts single phase.
If you have any questions regarding this sec-
tion, please call True at 1-(800)-325-6152.