12
PROBLEM POSSIBLE 
CAUSE
REMEDY
Unit not cold enough.
Control set too 
Turn control knob 
warm
CLOCKWISE to set 
Check temperatures 
temperature colder: 
(see introduction for 
Allow 24 hours for 
specific temperatures)
temperature to stabilize
Light staying on 
Adjust door so light 
switch bracket contacts 
switch plunger:  See 
DOOR ADJUSTMENT
Airflow to front 
Airflow must not be 
grille blocked 
obstructed to front grille. 
See INSTALLATION 
Dirty condenser 
Clean condenser: 
coils 
See CLEANING AND 
MAINTENANCE
Door gasket not 
Adjust door: See 
sealing properly 
DOOR ADJUSTMENT
Unit is too cold.
Control set too cold 
Turn control knob 
COUNTER-CLOCKWISE
Check temperatures 
to set temperature 
(see introduction for 
warmer:  Allow 24 hours 
specific temperatures)
for temperature to 
stabilize.
No interior light 
Loose or burned 
Tighten or replace 
out bulb
bulb: See BULB 
REPLACEMENT. 
Light won’t go out 
Light on/off switch 
Turn switch to off.  
when door is closed 
is turned to ON.
See LIGHT SWITCH 
AND BULB.
Troubleshooting Guide
Never attempt to repair or perform maintenance on the unit
until the main electrical power has been disconnected.
!
!
DANGER
41739 Origins WC Body.qxd  10/22/03  1:40 PM  Page 12