TROUBLESHOOTING
4-1-3. Self-diagnostic function
1-1) Micom operates self-diagnostic function to check the temperature sensor condition
within 1 second when the refrigerator turned On initially.
1-2) If bad sensor is detected by the self-diagnostic function, the applicable display LED will
blink for 0.5 sec.
At this moment, there is no beep sound.(Refer to self-diagnostic CHECK LIST)
At this moment, there is no beep sound.(Refer to self-diagnostic CHECK LIST)
1-3) Self-diagnostic button is recognized only when the error is displayed by the bad sensor.
Display does not operate normally but temperature control will be controlled by the
emergency operation.
emergency operation.
1-4) When the error is detected by self-diagnosis, the error can be canceled automatically if
all troubled sensors are corrected or Self-diagnostic function key (Energy Saver Key +
Alarm/Lighting Key ) are pressed simultaneously for 8 seconds.
(Return to normal display mode)
Alarm/Lighting Key ) are pressed simultaneously for 8 seconds.
(Return to normal display mode)
2-1) If Energy Saver Key + Alarm/Lighting Key are pressed simultaneously for 6 seconds
during normal operation, the temperature setting display will operate for 2 seconds
(ON/OFF 0.5sec each).
If Energy Saver Key + Alarm/Lighting Key are pressed simultaneously for 8 seconds
(including above 2 seconds), self-diagnostic function will be selected.
(ON/OFF 0.5sec each).
If Energy Saver Key + Alarm/Lighting Key are pressed simultaneously for 8 seconds
(including above 2 seconds), self-diagnostic function will be selected.
2-2) At this moment, self-diagnostic function will be returned with buzzer sound 'ding-dong'.
If there is an error, display of error will be operated for 30 seconds and then return to
normal condition whether problem is corrected or not.
(Refer to self-diagnosis CHECK LIST)
normal condition whether problem is corrected or not.
(Refer to self-diagnosis CHECK LIST)
2-3) Input by button is not accepted during self-diagnostic function.
1) Self-diagnostic function in the Initial power ON
2) Self-diagnostic function during normal operation
① If Energy Saver Key + Alarm/Lighting Key are pressed simultaneously
for 8 seconds, the error mode by self-diagnosis will be canceled.
2¢ (-17¡ ) is recommended
38¢ (3¡ ) is recommended
2¢ (-17¡ ) is recommended
38¢ (3¡ ) is recommended