Fujitsu MAN3184 User Manual

Page of 302
C141-E124-01EN
4 - 55
4.2.7.2 Reference temperature (Page 0D, Code 0001)
                             Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0001' (Parameter code)
(Temperature)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
1
0
0
0
0
1
1
7
X'02' (Parameter Length)
8
X'00' (Reserved)
11
Reference Temperature (degrees Celsius)
The Reference Temperature reflect the maximum reported sensor temperature in degrees Celsius at
which the device can operate continuously without degrading the device's operation or reliability
outside the limits specified by the manufacturer of the device.
4.2.8
Start-stop cycle counter page (X'0E')
                             Bit
Byte
7
6
5
4
3
2
1
0
0
0
0
0
0
1
1
1
0
1
X‘00’ (Reserved)
2
Page Length (MSB)
3
Page Length (LSB)
All of the following parameters have this header.
Page Length will be defined based on the value of Parameter Pointer.  (CDB 5-6)