Electrical Requirements
Observe all governing codes and ordinances. 
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 (latest 
edition), or CSA Standards C22.1-94, Canadian Electrical Code, 
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 
and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 
required.
It is not recommended to ground to a gas pipe.
It is not recommended to have a fuse in the neutral or ground 
circuit.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial rating plate. 
The model/serial plate is located behind the filter on the rear 
wall of the hood.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
INSTALLATION INSTRUCTIONS
Prepare Location
NOTE: For vented installations, it is recommended that the vent 
system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting method to 
use: roof or wall.
2. Select a flat surface for assembling the range hood. Place 
covering over that surface.
3. Using two or more people, lift the range hood onto covered 
surface.
4. If cabinet has recessed bottom, add wood filler strips on each 
side. Install screws to attach filler strips in locations shown.
Determine Wiring Hole Location
Cut only one 1
¹⁄₄" (3.2 cm) diam. wiring access hole. See Step 2 
for wiring hole location instructions. Either wiring hole can be 
used. 
1. Determine and clearly mark a vertical centerline on the wall 
and cabinet in the area the vent opening will be made.
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.
Wood filler strips 
 
(recessed cabinet
bottoms only)
Cabinet
bottom
Wall
3"
(7.6  cm)
3"
(7.6  cm)
A. Centerline
A