Kenmore 31133 User Manual

Page of 14
12
V
ERTICAL
 
DISCHARGE
 
ONLY
:
6.  Mount the 8” round adapter/damper (included in a separate 
box) to the hood using 4 no. 8 x 3/8” sheet metal screws 
(included).
FINALIZE THE  INSTALLATION
1. Remove protective plastic film covering the lower flue 
only.
  Peel off both corners at the top of the upper fl ue.
  Position the lower fl ue rear notches down (the ones with the 
45° angle).
  Gently slide upper fl ue inside lower fl ue, louvers end fi rst 
(so that louvers are hidden inside lower fl ue, as they are not 
needed).
HO0144
  Both lower and upper fl ues are included with the hood, but 
for a 10 foot ceiling, discard the provided upper fl ue  and 
use the optional extension fl ue, part no. 31131 (purchase 
separately).
NOTE
2. Carefully slide in place decorative fl ue base (notches end 
fi rst) between the shaded part and the exterior wall of the 
top of the hood.
HO0143
L
OWER
 
FLUE
 
REAR
 
NOTCH
L
OWER
 
FLUE
 
REAR
 
NOTCH
L
OUVERS
U
PPER
 
FLUE
 
TOP
 
CORNERS
HJ0041
V
ERTICAL
 
DISCHARGE
 
ONLY
:
7.  Plug hood power cord into the outlet.
  Slide a 8” metal round duct over the adapter/damper. Use 
metal foil duct tape to seal the joint.
HJ0037
INSTALL THE  HOOD
INSTALL THE  HOOD