3. Carefully remove cabinet from carton by lifting out unit
using straps provided.
CAUTION: Do not attempt to lift this air curtain by its
louver or damage may result.
4.  Unscrew  six  (6)  knurled  nuts  and  remove  air  intake
grille. (See Figure 3.)
Figure 3 - Removing Air Intake Grille
5. Carefully  disconnect  motor  electric  cord  plug
assembly and remove two wing nuts on blower base.
(See Figure 4.)
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
OBSERVE THE  FOLLOWING:
1. Use  this  unit  only  in  the  manner  intended  by  the
manufacturer.  If  you  have  questions contact  the
manufacturer.
2.  Before  servicing  or  cleaning  unit,  switch  power  off  at
service panel and lock service panel to prevent power
from being switched on accidentally.
3. Installation work and electrical wiring must be done by
qualified  persons  in  accordance  with  all  applicable
codes and standards, including fire rated construction.
4.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not
damage electrical wiring or other hidden utilities.
5.  Make  certain  that  the  power  source  conforms  to  the
electrical requirements ofthe unit. Disconnect power
before  installing  or  servicing.  If  the  power  disconnect
is out of sight, lock it in the open position and tag it to
prevent unexpected application of power. Failure to do
so could result in fatal electrical shock.
WARNING: DO NOT DEPEND UPON A THERMOSTAT
OR OTHER SWITCH AS THE SOLE MEANS OF
DISCONNECTING POWER WHEN INSTALLING OR
SERVICING THE  UNIT. ALWAYS  DISCONNECT
POWER AT THE MAIN CIRCUIT BREAKER AS
DESCRIBED ABOVE. FAILURE TO DO SO COULD
RESULT IN FATAL ELECTRIC SHOCK.
Figure 4 - Removing Motor/Blower Assembly
6. To  remove  motor/blower  assembly,  lift  from  rear  of
motor  housing  to  prevent  damage  and  misalignment
to shaft and blower wheels.
NOTE:  Unit  is  shipped  with  styrofoam  motor  support
block which must be discarded at this time.
NOTE:  After  unpacking  unit,  inspect  carefully  for  any
damage that may have occurred during transit. Check for
loose, missing or damaged parts.
6.  All  wiring  should  be  done  by  a  qualified  electrician,
using copper wire only and in accordance with the
National  Electrical  Code  (NEC),  all  applicable  code
and  ordinances,  and  all  sections  of  this  manual. Any
variance  voids  the  warranty  and  may  create  unsafe
conditions.
7. Special  attention  must  be  given  to  any  grounding
information  pertaining  to  this  product.  To  prevent  the
risk  of  electrocution,  the unit  must be  securely and
a d e q u a t ely grounded. This should be accomplished
by  connecting  a  grounded  conductor  between  the
service panel and the grounding lug or green lead wire
provided  in  the  wiring  compartment.  To  ensure  a
proper  ground,  the  grounding  means  must  be  tested
by a qualified electrician.
8.  Do  not  insert  fingers  or  foreign  objects  into  the  air
curtain. Do not block or tamper with it in any manner
while  it  is  in  operation.  Do  not  touch  it  while  in
operation or just after it has been turned off, as some
parts may be hot enough to cause injury.
9. This  product  must  NOT be  used  in  potentially
dangerous  locations  such  as  hazardous  locations
where  flammable,  explosive,    chemical  laden,  or  wet
atmospheres are present.
10. Do not attach ductwork to this product or attempt to
use  it  as  a  make-up  air  heater.  Such  use  voids  the
warranty and may create unsafe conditions.
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT USE THIS AIR CURTAIN
WITH ANY SOLID STATE SPEED CONTROL DEVICE.
General Safety Information
Unpacking (Continued)
2