Southbend G-72-M User Manual

Page of 52
T
ROUBLESHOOTING
H
EAVY 
D
UTY 
C
OUNTERLINE
P
AGE 
32
O
WNER
M
ANUAL 
1182845 
REV 
8
TROUBLESHOOTING
T
ROUBLESHOOTING
Consult the following table for troubleshooting guidance.
Problem
Look for -
No burners or pilots will turn on
– Main gas supply to unit is “OFF”
Problem with a particular burner
– Valve for that burner in “OFF” position
– Pilot out
– Burner not level in support brackets
– Clogged burner ports
– Clogged burner venturi
– Clogged burner orifice
– Wrong type of burner orifice
– Burner orifice out of alignment with burner
Griddle will not heat up
– Main gas supply to griddle is “OFF”
– Pilot(s) not lit
– Fault in thermostat(s)
– Clogged orifice or burner ports
Lava-rock charbroiler has “hot spots”
– Stacked-up lava-rock briquettes (briquettes should be
spread out evenly)
Burners produce excessive carbon deposits
– Incorrect gas type
– Incorrect orifice size
– Incorrect supply pressure
– Incorrect burner air mixer adjustment
– Burner orifice out of alignment with burner
Pilot produces excessive carbon deposits
– Pilot gas not adjusted properly
– Incorrect pilot orifice
Pilot will not stay lit
– Pilot not adjusted properly
– Clogged or dirty orifice
– Draft condition
– Improper ventilation system
– Air in gas line
– Valve end of thermocouple corroded or loose
– Pilot shield needs to be moved closer to pilot
– Improper gas pressure
– Incorrect gas supply size (not enough volume)
– Fault in thermocouple
Burner makes a slight popping noise when turned off
– This is normal when using propane gas
Electronic ignition module will not generate a spark
– Dead battery in ignition module
– Fault in spark module
– Fault in switch