Alto-Shaam 500-2D User Manual

Page of 27
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 6
1. 
An identification tag is permanently mounted on 
the cabinet.
2. 
Plug cabinet into a properly grounded receptacle 
ONLY, positioning the unit so the power supply 
cord is easily accessible in case of an emergency.
  Arcing will occur when connecting or 
disconnecting the unit unless all controls are in 
the “OFF” position.
3. 
If necessary, a proper receptacle or outlet 
configuration as required for this unit, must be 
installed by a licensed electrician in accordance 
with applicable, local electrical codes.  
c A u T I O N
THIS SECTION IS PROVIDED FOR THE ASSISTANCE 
OF QUALIFIED SERVICE TECHNICIANS ONLY AND 
IS NOT INTENDED FOR USE BY UNTRAINED OR 
UNAUTHORIZED SERVICE PERSONNEL.
    D A N g E r
DIScONNEcT uNIT frOM 
pOwEr SOurcE bEfOrE 
cLEANINg Or SErVIcINg.
D A N g E r
To avoid electrical shock, this 
appliance MUST be adequately 
grounded in accordance with local 
electrical codes or, in the absence of 
local codes, with the current edition 
of the National Electrical Code ANSI/
NFPA No. 70.  In Canada, all electrical 
connections are to be made in 
accordance with CSA C22.1, Canadian 
Electrical Code Part 1 or local codes.
E L E c T r I c A L
I N S T A L L A T I O N
Wire diagrams are located inside the bonnet of the unit.
ELEcTrIcAL
 
voltage
 
phase
 
cycle
/
hz
 
amps
 kW 
 
 
120 
60 
5.3 
0.64 
nema
 5-15
p
 
 
    
 
15a, 125V 
plug
  208-240  1 
60 
2.7 
0.64 
nema
 6-15
p
 
 
     
15a, 250V 
plug
 
230 
50/60 
2.6 
0.59 
cee
 7/7, 
 
 
 
 
 
 
220-230V 
plug
For CE approved units:  To prevent an electrical 
shock hazard between the appliance and other 
appliances or metal parts in close vicinity, an 
equalization-bonding stud is provided. An 
equalization bonding lead must be connected to 
this stud and the other appliances / metal parts 
to provide sufficient protection against potential 
difference. The terminal is marked 
with the following symbol.
NOTE
:   
Where local codes and CE regulatory 
requirements apply, appliances must be 
connected to an electrical circuit that is 
protected by an external GFCI outlet.
hard wired models:
Hard wired models must be equipped with a 
country certified external allpole disconnection 
switch with sufficient contact separation.
If a power cord is used for the connection of the 
product an oil resistant cord like H05RN or H07RN 
or equivalent must be used.