Hoshizaki KM-1900SRH/3 User Manual
28
KM-1900SAH/3
KM-1900SRH/3
KM-1900SRH/3
Bin Drain Outlet
3/4" FPT
3/4" FPT
Icemaker Water Supply Line Shut-Off Valve
Icemaker Water Supply Line Drain Valve
Icemaker Water Supply Inlet 1/2" FPT
Icemaker
Drain Outlet
3/4" FPT
Drain Outlet
3/4" FPT
Condensation
Drain Outlet
3/8" OD Hard
Tube
Drain Outlet
3/8" OD Hard
Tube
Bin
Icemaker
Remote Condenser Line Set Connections
Separate piping to approved drain.
Leave a 2 inch (5 cm) vertical air gap
between the end of each pipe and the
drain.
Leave a 2 inch (5 cm) vertical air gap
between the end of each pipe and the
drain.
2-inch (5-cm)
air gap
air gap
Floor
Drain
Fig. 17
1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent
is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.
Minimum 3/8" Nominal
ID Copper Water Tubing
ID Copper Water Tubing
Minimum 3/4"
Nominal ID Hard Pipe
Nominal ID Hard Pipe
Vent Tube
Vent Tube