Hoshizaki KML-200MAE User Guide
26
4. PERFORMANCE DATA
[a] KML-200MAE
Note: Pressure data is recorded first 5 minutes in freezing cycle.
The data without *marks should be used for reference.
* We reserve the right to make changes in specifications and design without prior notice.
AMBIENT
WATER TEMP. ( °F/°C )
TEMP. ( °F/°C ) 50/10
70/21
90/32
70/21
*250 (113)
240 (109)
220 (100)
80/27
241 (109)
226 (103)
210 ( 95)
90/32
230 (104)
*214 ( 97)
199 ( 90)
100/38
218 ( 99)
203 ( 92)
187 ( 85)
70/21
*770
776 801
80/27
774 784 818
90/32
776
*790
821
100/38
787
797
850
70/21
*81 ( 0.31 ) 73 ( 0.28 ) 63 ( 0.24 )
80/27
75 ( 0.28 ) 62 ( 0.24 ) 54 ( 0.20 )
90/32
73 ( 0.28 )
*54 ( 0.20 ) 44 ( 0.17 )
100/38
71 ( 0.27 )
51 ( 0.19 )
*36 ( 0.14 )
70/21
*20
21
28
80/27
21 23 32
90/32
21
*24
32
100/38
24
26
*40
70/21
*2.5 2 2
80/27
2 2 2
90/32
2
*2 2
100/38
3
2
*2
70/21
*260
268
276
80/27
266
278
284
90/32
268 *286
293
100/38
268
288
*300
70/21
*25
26 36
80/27
26
28 42
90/32
26
*30
42
100/38
31
33
*53
TOTAL HEAT OF REJECTION
5980 Btu/h [AT 90°F (32°C) / WT 70°F (21°C)]
APPROXIMATE
ICE PRODUCTION
PER 24 HR.
ICE PRODUCTION
PER 24 HR.
lbs./day (kg./day)
APPROXIMATE ELECTRIC
CONSUMPTION
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
CONSUMPTION PER 24 HR.
gal./day (m
3
/day)
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
PSIG
SUCTION PRESSURE
PSIG (kg/cm
2
G)