Hoshizaki KM-260BAH User Manual

Page of 81
25
b) CIRCULATE
When the service switch is active and placed in the “CIRCULATE” position, power is 
supplied to the pump only. This operation can be used to circulate cleaner for extended 
periods of time over the outside surface of the evaporator.
c) WASH
This machine utilizes a solenoid operated wash (bypass) valve. When the service switch 
is active and placed in the “WASH” position, power is supplied to the pump and cleaning 
valve. This operation is used to circulate cleaner and sanitizer over both the inside and 
outside of the evaporator.
Fig. 3
Control Switch
Service Switch
SER
VICE
ICE
OFF
DRAIN
WASH
CIRCULA
TE