Hoshizaki KM-260BAH User Manual

Page of 81
30
[b] KM-260BAH
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
10sec
     HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 50 sec
in harvest cycle (Ver 3.1 or
later)
6min
60sec
               HARVEST CYCLE
Thermistor senses 9°C after more than
8 min 50 sec in harvest cycle (Ver 3.1
or later)
6min
3min
10sec
FREEZE CYCLE
PART NAME
HARVEST CYCLE
(INITIAL)
FREEZE CYCLE
HARVEST CYCLE
(AFTER BIN FULL)
HARVEST CYCLE
(INCLUDING DRAIN)
FREEZE CYCLE
F
REEZE CYCLE
H
ARVEST CYCLE
BIN FULL
HOT GAS VALVE
FAN MOTOR
ON
OFF
ON
Program Ver 2.5
or earlier
(Auxiliary Code:
V-0 or earlier
)
ON
OFF
WATER VALVE
ON
OFF
CLEANING VALVE
ON
OFF
DRAIN VALVE
FLOAT SWITCH
ON
RELAY: X4
(WV)
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
CONT
ROL B
OA
RD
RELAY: X6
(DV)
RELAY: X1
(COMP)
RELAY: X2
(HV/FM)
ON
RELAY: X3
(PM)
OFF
OFF
BIN CONTROL
SWITCH
ON
OFF
OFF
PU
MP MO
TOR
Program Ver 3.2
or later
(Auxiliary Code:
V-1 or later
)
POWER SWITCH
ON
HARVEST CYCLE
COMPRESSOR
ON
OFF
1°C
OFF
9°C
5°C
THERMISTOR
Max 6 min
5 sec
Max 6 min
Max 6 min
10 sec
Max 6 min
15 sec
10 sec
90 sec
Max 6
10 sec
10 sec
10 sec
Max 6 min
10 sec
Max 6 min
Max 6 min