Hoshizaki KM-260BAH User Manual

Page of 81
44 
6. OTHER 
 
PROBLEM POSSIBLE 
CAUSE 
REMEDY 
1. Completely 
disconnected and 
dropped inside bin. 
1. Place in position. 
2. Detector broken. 
2. Replace. 
3. Detector out of position.
3. Place in position. 
4. Defective reed switch. 
4. Check for continuity and 
replace. 
5. Reed switch out of 
position. 
5. Place in position. 
a) Bin Control Switch
6. Magnet disconnected 
from detector. 
6. Place in position. 
[1] Icemaker will 
not stop when 
bin is filled with 
ice. 
b) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
a) Pump Motor 
1. Bearings worn out. 
1. Replace. 
1. Bearings worn out. 
1. Replace. 
2. Fan blade deformed. 
2. Replace fan blade. 
b) Fan Motor 
3. Fan blade does not 
move freely. 
3. Replace. 
1. Bearings worn out, or 
cylinder valve broken. 
1. Replace. 
c) Compressor 
2. Mounting pad out of 
position or loose 
hold-down bolt. 
2. Reinstall. 
[2] Abnormal 
noise 
d) Refrigerant Lines 
1. Rub or touch lines or 
other surfaces. 
1. Reposition. 
[3] Ice in Storage 
Bin often 
melts. 
a) Bin Drain 
1. Plugged. 
1. Clean.