Hoshizaki KML "H" SERIES User Guide
39
[d] CONTROLS AND ADJUSTMENTS
The Dip Switch is factory-adjusted to the following positions:
FOR MODELS WITH THERMOSTAT:
Switch Nos. 1 and 2:
Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature
The Defrost Timer starts counting when the Thermistor reads a certain temperature
at the Evaporator outlet.
Switch Nos. 3 and 4:
Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker
When a freeze cycle is completed, the Pump Motor stops, and the icemaker
resumes operation in 2 seconds. Then the Pump Motor drains the Water Tank
for the time determined by the Drain Timer. The Drain Timer also determines the
time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
for the time determined by the Drain Timer. The Drain Timer also determines the
time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
Switch Nos. 5 and 6:
Used for adjustment of the Drain Counter.
The Pump Motor drains the Water Tank at the frequency determined by the Drain
The Pump Motor drains the Water Tank at the frequency determined by the Drain
Counter.
FOR MODELS WITH MECHANICAL BIN CONTROL:
DIP SWITCH NO.
1
2
3
4
5
6
7
8
9
10
KML-250 MAH
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
KML-250 MWH
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
ON
350M_F, 350M_H
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
ON
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
KML-600MRF, MRH
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
DIP SWITCH NO.
1
2
3
4
5
6
7
8
9
10
KML-250 MAH
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
KML-250 MWH
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
350M_F, 350M_H
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
KML-600MRF, MRH
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON