33
2. KM-1301SWH-E (water-cooled) 
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1330
603
1304
591
1239
562
80/27
1310
594
1269
576
1189
539
90/32
1304
591
1240
562
1165
528
lbs./day   kg./day
100/38
1281
581
1222
554
1096
497
70/21
80/27
90/32
watts
100/38
70/21
1335
5.05
1425
5.40
1971
7.46
80/27
1404
5.31
1544
5.85
2324
8.80
90/32
1425
5.40
1643
6.22
2335
8.84
gal./day    m
3
/day
100/38
1741
6.59
1805
6.83
2971
11.25
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
238
16.7
239
16.8
249
17.5
80/27
239
16.8
240
16.9
256
18.0
90/32
239
16.8
241
16.9
255
17.9
PSIG     kg/cm
2
G
100/38
244
17.2
244
17.2
267
18.8
70/21
50
3.5
51
3.6
52
3.6
80/27
50
3.5
51
3.6
52
3.7
90/32
51
3.6
52
3.7
53
3.7
PSIG     kg/cm
2
G
100/38
51
3.6
52
3.7
54
3.8
19,382  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,600 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
117 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
       less than 10 PSIG
32
34
32
33
34
32
33
2.4
4.2
3.1
3.7
3.0
2.4
3.8
31
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
1790
1780
1780
1780
1786
1780
1780
1780
34
35
36
38
1799
1810
1806
1830
HARVEST CYCLE TIME
HEAD PRESSURE
3.4
2.9
3.7
2.2
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE