19
3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely 
affect performance and warranty coverage. For more information, contact 
Hoshizaki Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
S1 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
FS-1022MLH-C
ON OFF OFF OFF OFF OFF ON
ON OFF OFF
Infrared Sensor Shutdown Delay
Continuous Dispensing Timer 
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Bin Control Selector 
Mechanical Backup Bin Control Shutdown Delay 
Normally off (factory use)
b) Infrared Sensor Shutdown Delay (S1 dip switch 1, 2, 3)
Infrared sensor shutdown delay is the delay between the infrared sensor detecting ice 
(yellow LED flashing or steady) and the start of the shutdown sequence. For dispenser
unit applications, the ice level at shutoff may need to be adjusted depending on the 
dispenser agitation or dispense method. Increasing the shutdown delay setting allows for 
a higher level of ice in the bin before the icemaker shuts down. For a typical dispenser 
unit application, a 100-second shutdown delay is recommended. When used with a 
standard Hoshizaki storage bin, any shutdown delay setting is acceptable.
 WARNING
Increasing the shutdown delay allows a higher level of ice in the dispensing 
unit/storage bin before shutdown. This could lead to icemaker movement or ice 
overflow.
S1 Dip Switch Setting
Infrared Sensor Shutdown Delay
No. 1
No. 2
No. 3
OFF
OFF
OFF
0 Seconds
ON
OFF
OFF
100 Seconds (1.6 minutes) (Factory Default)
OFF
ON
OFF
1100 Seconds (18.3 minutes)
OFF
OFF
ON
1650 Seconds (27.5 minutes)
ON
ON
OFF
2200 Seconds (36.7 minutes)
OFF
ON
ON
0 Seconds
ON
ON
ON
0 Seconds