Hoshizaki KM-501MWH User Manual

Page of 55
55
. Remove the water from the potable water supply line:
) Remove the front panel (except water-cooled model).
) Move the control switch on the control box to the "OFF" position.
3) Wait 3 minutes.
4) Close the potable water supply line shut-off valve and open the potable water supply 
line drain valve.
5) Allow the line to drain by gravity.
6) Attach compressed air or carbon dioxide supply to the potable water line drain valve.
7) Move the control switch to the "ICE" position.
8) Blow the potable water line out using compressed air or carbon dioxide.
3. Drain the potable water tank:
) Turn off the power supply.
) Move the control switch to the "OFF" position.
3) Drain the water tank by removing the base 
cover and one end of the pump tubing. See 
Fig. 5.
4) Replace the pump tubing and the base 
cover in their correct positions.
5) Remove all ice from the storage bin, and 
clean the storage bin.
6) Replace the front panel in its correct position.
7) Close the drain valve.
Fig. 5