Hoshizaki KM-1301SRH/3 User Manual

Page of 84
45
3. KM-1301SWH (water-cooled) 
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1318
598
1319
599
1249
567
80/27
1319
598
1321
599
1211
549
90/32
1319
599
1323
600
1228
557
lbs./day   kg./day
100/38
1281
581
1301
590
1141
518
70/21
80/27
90/32
watts
100/38
70/21
1407
5.33
1527
5.78
2049
7.76
80/27
1499
5.67
1686
6.38
2406
9.11
90/32
1527
5.78
1818
6.88
2465
9.33
gal./day    m
3
/day
100/38
1861
7.04
1969
7.46
3060
11.58
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
235
16.5
236
16.6
246
17.3
80/27
236
16.6
237
16.7
253
17.8
90/32
236
16.6
238
16.7
252
17.7
PSIG     kg/cm
2
G
100/38
241
16.9
241
17.0
264
18.6
70/21
50
3.5
50
3.5
52
3.6
80/27
50
3.5
49
3.5
52
3.7
90/32
50
3.5
49
3.4
52
3.6
PSIG     kg/cm
2
G
100/38
51
3.6
50
3.5
54
3.8
17,600 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,300 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
120 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
       less than 10 PSIG
31
31
32
2.4
4.5
3.2
3.9
3.1
31
33
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
1755
1746
1754
1760
1766
1740
1744
1746
33
34
34
36
1767
1782
1786
1810
31
32
32
HARVEST CYCLE TIME
3.5
3.0
3.9
2.2
2.4
4.0
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
HEAD PRESSURE
ENG.F-011.1.0205