3  ELECTRICAL GROUNDING INSTRUCTIONS
This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. 
It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National 
Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces risk 
of electric shock by providing an escape wire for the electric current.
WARNING
 - 
Improper use of the grounding plug can result in 
a risk of electric shock.
Electrical Requirements
The  oven  is  equipped  with  a  3-prong  grounding  plug.  DO 
NOT  UNDER  ANY  CIRCUMSTANCES  CUT  OR  REMOVE 
THE  GROUNDING  PIN  FROM  THE  PLUG.  DO  NOT  USE AN 
EXTENSION CORD.
The Power Supply Cord and plug must be connected to a sepa-
rate 120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, single 
grounded receptacle. The receptacle should be located inside the 
cabinet directly above the Microwave Oven mounting location as 
shown in Figure 2.
NOTE:
1.  If  you  have  any  questions  about  the  grounding  or  electrical 
instructions, consult a qualified electrician or serviceperson.
2.  Neither Sharp nor the dealer can accept any liability for damage 
to the oven or personal injury resulting from failure to observe 
the correct electrical connection procedures.
Radio or TV Interference
Should there be any interference caused by the microwave oven 
to your radio or TV, check that the microwave oven is on a different 
electrical circuit, relocate the radio or TV as far away from the oven 
as feasible or check position and signal of receiving antenna.
4  HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely 
do not use plastic duct. Check that all connections are made securely. Please read the following carefully: 
Exhaust connection: The hood exhaust has been designed to connect to a standard 3-1/4” x 10” rectangular 
duct. If round duct is required, a rectangular-to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be 
used, care should be taken to align the exhaust with the 
space between the studs, or wall should be prepared 
at the time it is constructed by leaving enough space 
between wall studs to accommodate exhaust.
Maximum duct length: For satisfactory air movement, 
the  total  duct  length  of  3-1/4”  x  10”  rectangular  or  6” 
diameter round duct should not exceed 140 feet.
Elbows,  adapters,  wall  caps,  roof  caps,  etc.  present 
additional resistance to air flow and are equivalent to a 
section of straight duct which is longer than their actual 
physical size. When calculating the total length, add the 
equivalent lengths of all transitions and adapters plus the length of all straight duct sections. Figure 3 shows the 
approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating 
air flow resistance equivalent, which should total less than 140 feet.