Figures 3, 4 and 5 contain many Microwave Drawer measurements 
for reference when planning the drawer’s location.
This Microwave Drawer can be installed below any electric or 
gas wall oven.
*  Can also be installed using an electrical outlet in an adjacent 
cabinet within the area where the provided electrical cord can 
reach. Power cord access hole in cabinet should be a minimum  
1
/
2
" diameter hole and deburred of all sharp edges.
 
IMPORTANT
 
Always allow sufficient power cord length to the 
electrical outlet to prevent tension.
  Always check electrical codes for requirements.
30" mICRoWAvE dRAWER mEASUREmENtS
NORMAL INSTALLATION STEPS
ANTI-TIP BLOCK INSTALLATION INSTRuCTIONS
To reduce the risk of tipping of the drawer, the Anti-Tip block must 
be properly installed located 14 13/16-inches above the floor on
which the Microwave Drawer will sit. The 6-inch Anti-Tip block 
must be provided by the installer. See Figures 1 and 6 (for 24") or 
Figures 3, 4 and 6 (for 30"). The Anti-Tip block prevents serious 
injury that might result from spilled hot liquids.
If the Microwave Drawer is ever moved to a different location, the 
ANtI-tIP BLoCk
Anti-Tip block must also be moved 
and installed. When installed to 
the wall, make sure that the screws 
completely penetrate the dry wall 
and are secured in wood or metal 
so that the block is totally stable. 
When fastening, be sure that the 
screws do not penetrate electrical 
wiring or plumbing.
Figure 6
4"
(101.6 mm)
5" (127 mm)
6"
(152.4 mm)
3 1/2"
(89 mm)
Suggested electrical
outlet location*
Anti-Tip block
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
A
B
C
D
E
F
G
H
I
J
K
L
M
M
N
O
P
Q
R
S
Figure 3
Figure 4
A
B
C
J
D
E
F
G
H
I
Figure 5
A. 84" (2133.6 mm) wall 
cabinet
B. Optional wall oven 
cutout illustrated in 
sketch
C. Suggested electrical 
outlet location*
D. 6" (152.40 mm)
E. Anti-Tip block
F.  3-1/2" (88.90 mm)
G. 5" (127 mm)
H. 4" (101.60 mm)
I.  2" (50.8 mm) minimum
J.  28-7/16" (722.3 mm) 
opening
K. Allow 3/16" (4.76 mm) 
overlap
L. 14-13/16" (376.24 mm)  
to bottom of Anti-Tip 
block
M. Allow 3/4" (19.05 mm) 
overlap
N.  23-1/2" (596.9 mm) 
minimum depth
O. 14-13/16" (376.24 mm) 
opening
P.  Allow 7/16" (11.11 mm) 
overlap
A. 6" (152.40 mm)
B. Suggested electrical 
outlet location*
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F.  4" (101.60 mm)
G. 28-7/16" (722.31 mm) 
opening
H. 14-13/16" (376.24 mm) 
to bottom of Anti-Tip 
block
I.  Allow 3/4" (19.05 mm) 
overlap
J.  23-1/2" (596.9 mm) 
minimum depth
Q. Floor must support 100 lb (45.4 kg)
R. 19" (482.6 mm) to top of floor (recommended)
S.  30" (762 mm) cabinet minimum
K. Allow 3/16" (4.76 mm) overlap
L. 36" (914.4 mm) countertop height
M. Allow 7/16" (11.09 mm) overlap
N. Floor must support 100 lb (45.4 kg)
O. 19" (482.6 mm) to top of floor (recommended)
P.  30" (762 mm) cabinet minimum
Q. 14-13/16" (376.24 mm) opening
A. 21-5/8" 
(549.28 mm)
B. 4-11/16" 
(119.06 mm)
C. 1-3/4" 
(44.45 mm)
D. 21-7/8" 
(555.63 mm)
E. 30" (762 mm)
F.  15" (381 mm)
G. 14-19/32" (370.68 mm)
H. 1-11/16" (42.86 mm) door thickness
I.  15" (381 mm) auto drawer opening
J.  4" (101.6 mm)