Electrical Requirements
Observe all governing codes and ordinances.
Required:
A 120 Volt, 60 Hz, AC only, 15- or 20-amp electrical supply 
with a fuse or circuit breaker.
Recommended:
A time-delay fuse or time-delay circuit breaker.
A separate circuit serving only this microwave oven.
Microwave Oven Preparation
1. Unplug microwave oven before proceeding with installation.
2. Remove any loose items inside microwave oven.
Duct Assembly
1. Remove 4 existing screws (2 on each side) from the 
microwave oven. The screws are located at the lower edge. 
These screws will be used in the next step.
2. Secure duct base to the microwave oven with the 4 existing 
screws removed in Step 2.
3. Secure left duct to outside panel of microwave oven with one 
9/16" screw, as shown.
Microwave Oven Installation
1. On the cutout floor, find and mark the centerline.
2. Use Template 1 to mark hole center for box screw. Be sure to 
align the center line of template to center line of cutout floor.
3. Using 7/64" drill, drill pilot hole into hole center marked in 
Step 2.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For all cord connected appliances:
The microwave oven must be grounded. In the event of 
an electrical short circuit, grounding reduces the risk of 
electric shock by providing an escape wire for the electric 
current. The microwave oven is equipped with a cord 
having a grounding wire with a grounding plug. The plug 
must be plugged into an outlet that is properly installed 
and grounded.
WARNING: 
Improper use of the grounding plug can 
result in a risk of electric shock. Consult a qualified 
electrician or serviceman if the grounding instructions are 
not completely understood, or if doubt exists as to whether 
the microwave oven is properly grounded. 
Do not use an extension cord. If the power supply cord is 
too short, have a qualified electrician or serviceman install 
an outlet near the microwave oven.
A. Duct base
B. Existing screws (4)
A. Left duct
B. 9/16" screw
A. Cutout floor
B. Center line
C. Cutout opening
A
B
A
B
A
B
C
14
²⁵⁄₃₂
"
(37.5 cm)