Smeg CH500 User Manual

Page of 13
11
GB
Fault finding
Fault
Possible cause
Remedy
No light in display.
There is not enough light for the solar  
sensor.
Turn on the light.
No control lamps are 
lit.
The appliance is switched off.
Power failure; the fuse is blown; the 
appliance is not plugged in correctly.
Check the plug and socket.
Check that power is connected. 
Reset the fuse. 
Temperature in freezer 
too high.
The ventilation grille is blocked.
The lid is not closed properly.
The quantity of fresh items placed 
in the freezer is greater than the 
capacity of the appliance.
Thick layer of frost and ice.
The thermostat is set too high.
Ensure unhindered air circulation.
Close the lid and wait a few hours.
Wait a few hours.
Defrost the freezer.
Set the thermostat to a lower 
temperature.
Temperature in freezer 
too low.
Super Freeze is activated.
The thermostat is set too low.
The lid is touching items stored in the 
freezer.
Switch Super Freeze off.
Set the thermostat to a higher 
temperature.
Reposition items inside the freezer 
and check that the lid closes tightly.
The freezer produces 
large quantities of frost.
Air humidity in the room is high.
Items placed in the freezer are giving 
off moisture.
Ventilate the room more often or 
move the freezer to a room with lower 
humidity.
Repack items stored in the freezer.
The lid cannot be 
opened.
There is underpressure in freezer.
Wait 2-3 minutes until the 
underpressure has been equalised 
and try again.
Vibration and unusual 
noise.
The appliance is not on a level 
surface.
The appliance is not free standing.
Baskets or partition are loose.
Position the freezer on a flat, level 
and stable surface.
Move the appliance away from other 
appliances or pieces of furniture.
Check movable fittings and reposition 
them.