John Lewis JLBICM 01 User Manual

Page of 32
 
 
9
Technical specifications 
 
Width 594 
mm
Depth 475 
mm
Height  
378  mm
Capacity of water reservoir 
2.5 l 
Net weight 
28 kg 
Gross weight 
31 kg 
Supply voltage 
230 V 
Rated power 
2000 W
Power absorbed by the heating element
1700 W
Power absorbed by the pump 
50 W 
Working pressure 
12 bar 
Fuse 13 
 
Electrical connection 
 
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. 
 
WARNING: THIS APPLIANCE MUSTBE EARTHED.
 
Should the appliance power supply cable need to be replaced, this must be carried out by a Service Force agent. The 
manufacturer declines any liability should this safety measure not be observed. 
Before switching on, make sure the electricity supply voltage is the same as that indicated on the applianceÊs rating plate. 
The appliance should be fitted with a 13amp plug. The plug should be fitted with a 13amp ASTA approved BS1363/A fuse. 
The mains lead of the appliance should be connected as described below. The wires in the mains lead are coloured in 
ng code: 
accordance with the followi
•  Green and Yellow – Earth 
•  Blue - Neutral 
•  Brown - Live  
 
In the plug the colours of the wires may not correspond with the markings identified with the 
terminals in your plug:  
 
1)  Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter "E" or the 
earth symbol or coloured green and yellow.  
2)  Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.  
3)  Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red. 
4)  Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over 
the outer sheath. 
 
THE PLUG MUST STILL BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN INSTALLED.  
 
THE APPLIANCE SHOULD NOT BE CONNECTED TO THE ELECTRICAL SUPPLY BY MEANS OF AN EXTENSION CABLE  
 
Permanent connection 
 
In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the 
electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required 
load in compliance with the current electrical regulations.  
The switch must not break the yellow and green earth cable at any point.