Viking VCWB300 User Manual

Page of 24
SEALED SYSTEM 
 
 
The sealed system consists of the following components (listed in order of refrigerant 
flow): 
 
1 condenser coil 
1 dryer assembly 
3 solenoid valves 
3 heat exchangers 
3 evaporators 
1 compressor 
1 discharge tube 
1 drain pan heater 
1 pre-condenser loop 
 
 
Refrigerant Type – HFC 134a 
 
Refrigerant Charge – 7.3 oz. 
 
Evaporator Temperature Range 
           14
°F  to  - 31°F 
 
Expanding Device – Cap tube 
 
Compressor Cooling: 
 
LBP 32
° C Ambient temp 98 to 140V 
    LBP 43
° C Ambient temp 98 to 140V 
 
Maximum Condensing Pressures: 
 Operating 
230 
psig 
 Peak 
293 
psig 
 
Electrical Data: 
 
Normal Voltage  115VAC / 60Hz 
 
Start Winding Resistance – 21.20
Ω (at 
   77
°F) ± 8%. 
Run Winding Resistance – 7.90
Ω (at 
 77
°F) ± 8%. 
Locked Rotor Amps (60Hz) – 9.80 
Amps. 
 
Full Load Amps (60Hz) – 1.20 Amps. 
 
 
  
  
 
5