178024
Supply voltage
400 V, 3N,
50/60
230 V, 3,
50/60
400 V, 3N,
50/60
230 V, 3,
50/60
Net weight - kg.
15
15
35
35
Total Power - kW
4.4
4.4
8.8
8.8
Front plates power - kW
2.2
2.2
2.2, 2.2
2.2, 2.2
Front plates dimension - mm
Ø 230
Ø 230
Ø 230, Ø
230
Ø 230, Ø
230
Back plates power - kW
2.2
2.2
2.2, 2.2
2.2, 2.2
Back plate dimensions - mm
Ø 230
Ø 230
Ø 230, Ø
230
Ø 230, Ø
230
    height
250
250
250
250
    depth
700
700
700
700
    width
400
400
800
800
External dimensions - mm
Power supply
Electric
Electric
Electric
Electric
KINF400
178023
KINF4002
178031
KINF800
178024
KINF8002
178032
CHARACTERISTICS
MODELS
TECHNICAL DATA
RANGE 
COMPOSITION
  
N 700: a range of over 100 models 
for the professional caterer designed 
to guarantee the highest level of 
performance, reliability, energy 
saving, safety standards and 
ergonomic operation. These 
concepts are reflected in the total 
modularity of the range that ensures 
numerous configurations, either 
free-standing or bridged. N700 
demonstrates how advanced 
technology can satisfy the needs of 
the professional caterer.
The models detailed on this sheet 
are infrared cook tops available in 
half or full module.
FUNCTIONAL AND 
CONSTRUCTION 
FEATURES
 
 
Ceramic glass top, 6 mm thick, 
lying flush to the stainless steel 
frame for smooth pan movement and 
ease of cleaning.
 
The cooking top is sealed to 
prevent liquid infiltration inside the 
unit.
 
Heating of the infrared cooking top 
is via heat radiation produced by 
ultra high powered electric elements.
 
Radiant elements featuring 2 and 
4 concentric heating zones 
measuring 230 mm  in diameter 
allowing selection of the heating 
area to match the pot or pan size.
 
Energy regulation of each zone.
 
Warning light to indicate residual 
heat on the radiant surface for 
greater operator safety.
 F
ront panel in stainless steel with 
Scotch Brite finish.  
 
All models have right-angled side 
edges to allow flush fitting joins 
between units.
 
 
IPX4 water protection.
 
Main connections can be via the 
rear or the base of the unit.
 
All models can be easily mounted 
on open base cupboards or bridging 
supports.
 
All top models provided with 
service duct to facilitate installation.