Smeg PGF95-2 User Manual

Page of 17
 
Instructions for the installer
 
 
 
 
27 
2.3  Electrical connection 
Make sure that the voltage and capacity of the power supply cable conform 
to the data shown on the plate located under the protective cover. Do not 
remove this plate for any reason
 
The power supply cable plug and the wall socket must be of the same type 
and conform to the current electrical system regulations.  Check that the 
power line is adequately earthed. 
 
On the power line, install an all-pole disconnect switch with minimum contact 
gap of 3 mm located at an easily accessible position near the appliance. 
 
 
Do not use reducers, adapters or shunts. 
 
 
If the power cable is to be replaced, 
the wire section on the new cable must 
not be less than 0.75 mm
2
( 3 x 0.75 
cable), bearing in mind that the end 
tobe connected to the appliance must 
have the earth wire (yellow-green) at 
least 20 mm longer. 
 
Use only H05V2V2-F cable or similar which has a maximum temperature of 
90°C.  Any replacement needed should be carried out by a specialised 
technician who should make the mains connections according to the 
following diagram. 
 
L = brown 
N = blue 
 = yellow-green
 
 
 
 
The manufacturer declines all liability for injury to persons or animals 
and for damage to property resulting from non-observance of the above 
prescriptions or from tampering with any part of the appliance.