4. Quick service guide
 
MODEL: CMA 180 HIGH TEMP 
 
 
TECHNICAL ISSUE 
CAUSE 
SOLUTION 
Door magnetic reed switch problem 
Faulty magnetic reed switch 
 
Check wire connections inside control box 
  
  
Contact factory for new retrofit, corner P/N 
00566.10 straight P/N 00566.20   
Door mechanical switch problem 
Switch alignment issue 
Align switch 
  
Switch button broke 
Replace switch, P/N00562.00 
  
Delimer switch is in 
OFF
 position 
Flip to 
NORMAL
 position 
  
Loose wire connections 
Check and crimp connectors 
Pump motor not running 
Faulty # 3 micro switch in cam timer 
Replace micro switch, P/N 00411.00 
  
Faulty contactor 
Replace contactor, P/N 00404.85 
  
Faulty wash pump motor 
Replace wash pump motor, P/N 00201.00 
  
Faulty # 3 micro switch in cam timer 
Replace micro switch, P/N 00411.00 
Pump motor runs continuous 
Delimer switch is in 
DELIME
 position 
Flip to 
NORMAL
 position 
  
Faulty contactor 
Replace contactor, P/N 00404.85 
  
Booster heater thermostat not properly set 
Adjust thermostat 
  
Incoming main water temperature below 140 F Raise water temperature to 140 F 
Final rinse water below 180 degree F 
Tripped or faulty high limit switch  
Reset or replace high limit switch, P/N 17523.51
  
Faulty contactor  
Replace contactor, P/N 13003.17 
  
Faulty booster heater element  
Replace heating element, P/N 13417.67 
  
Scaled heating element 
De- scale heating element 
  
Thermostat is not properly adjusted  
Adjust thermostat 
  
Loose lead connection  
Check connectors and secure 
Wash tank heater is not operational 
Tripped or faulty high limit switch  
Reset or replace high limit switch, P/N 17523.51
  
Faulty float switch  
Replace float switch, P/N 13463.00 
  
Faulty contactor  
Replace contactor, P/N13003.50 
  
Faulty heating element  
Replace heating element, P/N 13417.65 
  
Water regulator not adjusted properly  
Adjust regulator to 18-20 PSI 
  
Clogged final rinse spray jets  
Clean jets 
Low water pressure at the final rinse 
Missing final rinse spray end cap  
Replace end cap, P/N 00308.17 
  
Low incoming water pressure from building  
Increase pressure 
Water solenoid leaks 
Scaled or dirty solenoid valve  
Clean valve 
  
Faulty solenoid valve diaphragm  
Replace diaphragm, P/N 00706.00 
  
Thermostat not properly set  
Adjust thermostat 
Wash water temperature too low/high 
Scaled heating element  
Clean scale, delime machine 
  
Faulty temperature gauge  
Replace gauge, P/N 03202.00 
  
Position or proper operation of door switch  
Adjust or replace door switch, P/N 00557.55 
  
Delimer switch is on 
OFF 
position  
Flip to 
NORMAL
 position 
  
Faulty 1st micro switch in cam timer 
Replace micro switch, P/N 00411.00 
Machine does not operate when the door is 
closed 
Check cam timer motor 
Replace timer if needed, P/N 00409.17 
  
Check ice cube relay  
Replace if faulty, P/N 00631.05 
  
Faulty wash pump contactor  
Replace contactor, P/N 00404.85 
MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 
Page