CMA Dishmachines CMA-180 User Manual

Page of 19
 
flexibility to permit the machine to be moved for cleaning without having to 
disconnect any wiring. 
ii. 
Run your dispenser wires through the conduit to the control box.  
iii. 
Run your probe wires to the control box. 
iv. 
With the machine’s power “OFF”, connect your detergent and rinse dispenser 
wires to the red and blue terminals of the power block supplied inside the control 
box.  The table that follows lists the function of each conductor of the multi-
conductor electrical cable. 
 
Wire Colors 
Circuit Voltage 
Function 
Gray/Violet 
200 VAC-249 VAC 50/60 Hz 
Main AC Power 
Brown 
200 VAC-249 VAC 50/60 Hz 
Main AC Power 
Black 
No Connection. Insulate this wire! 
This wire is LIVE! 
Yellow 
24 VAC-240 VAC 50/60 Hz 
Detergent Signal 
White/Yellow 
24 VAC-240 VAC 50/60 Hz 
Detergent Signal 
Violet 
24 VAC-240 VAC 50/60 Hz 
Rinse Signal 
White/Violet 
24 VAC-240 VAC 50/60 Hz 
Rinse Signal 
 
The individual conductors need to be connected as shown on the wire 
diagram below. Probe wires are to be striped, crimped on barrel male and 
female connectors provided, and connected to the pre-wired violet wires in 
the control box. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.03 
Page
  6