48. Failure Mode Request
 
Function 
The external control equipment inquires the detection of failures of the plasma 
monitor. 
Transmission Data 
  1FH   80H   60H   3FH   00H   CKS 
ACK 
The plasma monitor returns the following ACK: 
  7FH   60H   80H   3FH   02H   DATA00    DATA01    CKS 
 
DATA00: FAILURE MODE 1 
 
Bit 0 : PDP MODULE 
 
 
0: Abnormal 
 
 
 
1: Normal 
 
Bit 1 : 1: fixed (backup) 
 
Bit 2 : TEMPERATURE 
 
 
0: Abnormal 
 
 
 
1: Normal 
 
Bit 3 : FAN 
 
 
0: Abnormal 
 
 
 
1: Normal 
 
Bit 4 : TEMPERATURE SENSOR 
 
 
0: Abnormal 
 
 
 
1: Normal 
 
Bit 5 : 1: fixed (backup) 
 
Bit 6 : 1: fixed (backup) 
 
 
Bit 7 : 1: fixed (backup) 
 
DATA01: FAILURE MODE 2 
 
Bit 0-7 :    1: fixed (backup)