Pioneer PX-42XM3 User Manual

Page of 82
 
 
63 
 
63. GAMMA GAIN Data
 
Function 
External control apparatus changes Gamma of a plasma monitor. 
Transmission Data 
        DFH 80H 60H 13H 02H DATA00 DATA01 CKS 
            DATA00: GAMMA FLAG 
01H : Gamma change 
            DATA01: GAMMA   
00H :1 
                                       
 
01H :2 
                                       
 
02H :3 
                                       
 
03H :4 
ACK 
7FH 60H 80H 13H 01H DATA00 CKS 
            DATA00: GAMMA FLAG 
01H : Gamma change 
 
64. Running Sense
 
Function 
External control apparatus grasps the power supply state of a plasma monitor. 
A plasma monitor is made to recognize connection of PC CONTROL. 
Transmission Data 
      1FH 80H 60H 88H 00H CKS 
 
ACK 
      7FH 60H 80H 88H 01H DATA CKS 
      DATA: Bit0:Connect Condition   
                       
0: No connection 
                       
1: Connected 
                  Bit1 0: Fixed 
                       
1:- 
                  Bit2:Power Status   
                       
0:POWER ON 
                       
1:POWER OFF(STANBY) 
Bit3 0: Fixed 
Bit4 0: Fixed 
Bit5 0: Fixed 
Bit6 0: Fixed 
Bit7 0: Fixed