Wagner SprayTech Finish 370 User Manual

Page of 30
5
Finish 370 / 250
GB
SAFET Y REGULATIONS
1.8 
PREVENTION OF OCCUPATIONAL ILLNESSES
Protective clothing, gloves and possibly skin protection cream 
are necessary for the protection of the skin.
Observe the regulations of the manufacturer concerning coa-
ting materials, solvents and cleaning agents in preparation, 
processing and cleaning units.
1.9 
MAX. OPERATING PRESSURE
The permissible operating pressure for the spray gun, spray 
gun accessories, unit accessories and high-pressure hose 
must not fall short of the maximum operating pressure of 25 
MPa (250 bar or 3625 psi).
1.10 
HIGH-PRESSURE HOSE (SAFETY 
INSTRUCTIONS)
An electrostatic charging of spray guns and the high-pressure 
hose is discharged through the high-pressure hose. For this 
reason the electric resistance between the connections of the 
high-pressure hose must be equal to or lower than 1 M
Ω.
Only use WAGNER original-high-pressure 
hoses in order to ensure functionality, safety 
and durability.
1.11 
ELECTROSTATIC CHARGING (FORMATION OF 
SPARKS OR FLAMES) 
Electrostatic charging of the unit may occur 
during spraying due to the fl ow speed of 
the coating material. These can cause sparks 
and fl ames upon discharge. The unit must 
therefore always be earthed via the electrical 
system. The unit must be connected to an 
appropriately-grounded safety outlet.
1.12 
USE OF UNITS ON BUILDING SITES AND 
WORKSHOPS
The unit may only be connected to the mains network via a 
special feeding point with a residual-current device with INF 
≤ 30 mA.
1.13 
VENTILATION WHEN SPRAYING IN ROOMS
Adequate ventilation to ensure removal of the solvent vapors 
has to be ensured.
1.14 
SUCTION INSTALLATIONS
The are to be provided by the unit user in accordance with the 
corresponding local regulations.
1.15 
EARTHING OF THE OBJECT
The object to be coated must be earthed.
(Building walls are usually earthed naturally)
1.16 
CLEANING THE UNIT WITH SOLVENTS
When cleaning the unit with solvents, the 
solvent should never be sprayed or pumped 
back into a container with a small opening 
(bunghole). An explosive gas/air mixture can 
arise. The container must be earthed.
1.17 
CLEANING THE UNIT
Danger of short-circuits caused by water in-
gression!
Never spray down the unit with high-pressu-
re or high-pressure steam cleaners.
1.18 
WORK OR REPAIRS AT THE ELECTRICAL 
EQUIPMENT
These may only be carried out by a skilled electrician. No liabi-
lity is assumed for incorrect installation.
1.19 
WORK AT ELECTRICAL COMPONENTS
Unplug the power plug from the outlet before carrying out 
any repair work.