Yamaha RCX Series User Manual

Page of 76
5-
17
5
Specifications
5. CC-Link compatible module specifications
The CC-Link compatible module with the  label is compatible with CC-Link Ver. 1.10.
Limits on the station-to-station cable length, etc., can be eased by using the Ver. 1.10
compatible CC-Link cable. Refer to the master station PLC instruction manual compat-
ible with Ver. 1.10.
  Target controller 
RCX Series controller
  Remote station type  
Remote device station
  Number of occupied stations   
Fixed to four stations
  Station No. setting   
1 to 61 (rotary switch)
  Communication speed setting  
10M / 5M / 2.5M / 625K / 156Kbps (rotary switch)
  Number of CC-Link input/output points 
*1)
 
 
Monitor LED 
RUN, ERRL, SD, RD
Specification item 
CC-Link compatible module
*1)
 
Controller's I/O update intervals are 10ms at shortest, but actual I/O update intervals change depending 
 
on the update time for the master station.
Remote
input/output
Remote
register
Dedicated input 
: 16 points 
  
 
(11 points are currently used.)
General-purpose input  : 96 points
Dedicated output 
: 16 points 
  
 
(11 points are currently used.)
General-purpose output  : 96 points
Dedicated input 
:   2 words
General-purpose input  : 14 words 
Dedicated output 
:   2 words
General-purpose output  : 14 words 
c
CAUTION
For the names and description of
remote input/output signals and
remote registers, refer to the tables
shown in "1. Profile" and "2. Details
of remote input/output signals" in
this chapter.
c
CAUTION
The specifications and appearance
are subject to change without prior
notice.