Denso BHT-100B User Manual

Page of 208
143
Chapter 5.  Handling the CU-7000  (Option)
5.4.3 Interfacing with the Host Computer
This section describes how to start communication with the host computer in System
Mode.  The same may apply when you use a user program.
(1)
Turn the host computer on.
(2)
Plug the AC adapter of the CU-7000 into the wall socket.
(3)
Make sure that the BHT is turned off, then set it on the CU-7000.
(4)
Turn the BHT power on and run System Mode.  Set the communications environ-
ments (communications protocol, interface port, communications parameters,
and protocol options).
Regarding the communications protocol:  When using Ir-Transfer Utility C/Ir-
Transfer Utility E on the host computer, select the BHT-Ir protocol; when using
Transfer Utility, select the BHT-protocol.
Regarding the interface port:  Select the optical interface port.
(5)
On the host computer, initiate a communications program (e.g., Ir-Transfer Utility
C/Ir-Transfer Utility E/Transfer Utility, or equivalent).
(6)
To transfer data stored in the BHT to the host computer, select "3: UPLOAD" on
the SYSTEM MENU in System Mode.  To transfer data from the host computer to
the BHT, select "2: DOWNLOAD."  (For details, refer to Chapter 2, Section 2.5.)
The BHT and the host computer will start communications with each other via the
CU-7000.  The DATA LED will come on upon start of communications.  After
completion of communications, the LED will go off.
(7)
Unplug the AC adapter of the CU-7000 from the wall socket.