Layer 3 Switching
63
Rapier Switch Software Release 2.2.1
C613-02013-00 Rev A
Novell IPX
The advanced feature licence AT-RPFL3Upgrade is required for this feature.
The switch’s implementation of the Novell IPX protocol uses the term circuit to 
refer to a logical connection over an interface, similar to an X.25 permanent 
virtual circuit (PVC) or a Frame Relay Data Link Connection (DLC). The term 
interface is used to refer to the underlying physical interface, such as VLAN, 
Ethernet, Point-to-Point (PPP) and Frame Relay.
To create IPX circuit 1 with the Novell network number 129 over the admin 
VLAN, use the command:
ADD IPX CIRC=1 INTERFACE=vlan11 NETWORK=129 ENCAP=802.3
The command:
SHOW IPX CIRCUIT
displays information about the circuits configured for IPX (Figure 20).
Figure 20: Example output from the SHOW IPX CIRCUIT command.
IPX CIRCUIT information
Name ......................... Circuit 1
Status ....................... enabled
Interface .................... vlan11   (802.3)
Network number ............... c0e7230f
Station number ............... 0000cd000d26
Link state ................... up
Cost in Novell ticks ......... 1
Type20 packets allowed ....... no
On demand .................... no
Spoofing information
Keep alive spoofing .......... no
SPX watch dog spoofing ....... no
On SPX connection failure .... UPLINK
On end of SPX spoofing ....... UPLINK
RIP broadcast information
Change broadcasts ............ yes
General broadcasts ........... yes
General broadcast interval ... 60 seconds
Maximum age .................. 180 seconds
SAP broadcast information
Change broadcasts ............ yes
General broadcasts ........... yes
General broadcast interval ... 60 seconds
Maximum age .................. 180 seconds
Filter information
Filters ...................... none