Sony 8000SF User Manual

Page of 591
195
Setup
  Chapt
each device is recalled when a reset is made or the power is turned back on. 
(See “Selecting the start up state (Start Up)” (page 192).)
Note that the setup data in RAM can also be saved to the control panel hard disk 
or memory card.
Panel Setup
In panel setup, you carry out settings particular to the control panel.
You can make the following settings.
For details of the operations, see “Setup Relating to Operations From the 
Control Panel” in Chapter 16 (Volume 2).
Panel settings (Config)
• M/E Assign: Set the logical configuration of the M/E and P/P banks.
• M/E Operation: For each of the M/E and P/P banks, make operations 
possible, not possible, or disabled (Enable/Disable/Inhibit).
• Dual M/E Assign: Using two M/E banks, assign the shift and non-shift 
button rows of a single M/E bank.
• Dual M/E Xpt Swap: When a setting has been made for Dual M/E Assign, 
swap the shift and non-shift button rows.
• DSK Fader Assign: Carry out fader function assignment and key delegation 
for the key delegation buttons, in each of the maximum of four downstream 
key control blocks.
• External Bus Link: Make link settings relating internal switcher buses to 
routing switcher destinations.
• Key Trans Link: Select whether or not to link transitions between keyers, 
and if so which keyer to link to. You can set the links between keyers for each 
M/E bank separately.
• Reference Module: When a trackball module and a joystick module are both 
connected as device control blocks, select which is used as the reference.
• 10 Key Region Assign: Assign any regions to the region selection buttons 
in the numeric keypad control block. Also used for setting the regions 
included in the selection when the [All] button is pressed.
• Program Button: Make assignments for buttons of some control blocks 
such as assigning the buttons in a transition control block for controlling a 
VTR and assigning the Flexi Pad control block to macro operation.
• Compact Key Module Assign: You can select which keys can be operated 
with an independent key transition control block (simple type).
• M/E Operation Inhibit: For each M/E or P/P bank, enable or inhibit utility 
2 bus and key-related operations.