Setup Relating to the Router Interface and Tally 
Interface
Carry out settings relating to the interface with the routing switcher, and 
settings relating to the tally interface.
You can make the following settings.
Router interface setup (Router)
These settings are common to the parallel tally and serial tally.
• Matrix Size: Assign the switcher matrix of each switcher processor to S-Bus 
space, and select the matrix size and positioning level, source address 
settings, and so on.
• External Box: To obtain the signal selection status of external devices with 
a parallel input, assign a matrix as an external selector in the S-Bus space. 
Make the matrix size, assignment level, source address, and other settings.
• Alias Name Gp: Set the group number for an S-Bus description name to be 
displayed in the source name displays for a cross-point operation.
Tally interface setup (Tally)
Group tally settings (Group Tally)
• Tally Group: Select the group tally (Gp1 to 4 or Gp5 to 8) which can be 
used. (For the parallel tally, all groups can be used regardless of this setting.)
• S-Bus Tally Enable: Specify S-Bus tally enabled or disabled.
Wiring information input (Wiring)
Input the information which specifies the physical wiring between switcher 
and routing switcher or between two routing switchers.
These settings are common to the parallel tally and serial tally.
Tally enable settings (Tally Enable)
Specify the destination to be the reference for tally generation, and make 
various settings.
These settings are common to the parallel tally and serial tally.
• Tally Type: Specify the tally type. 
• Destination: Specify the address and level.
• Tally Enable: Specify the timing at which a tally is enabled.
Enable: Always enabled.
Disable: Always disabled.
Tally Input: Follow the tally input status.