Sony 8000SF User Manual

Page of 591
69
Wipes
  Chapt
the right, and the odd-numbered pairs move to the left. The value +100.00 
represents the maximum movement.
• The parameter V Offset determines the spacing in the vertical direction.
If a negative value is set, the even-numbered pairs of strip and slit move 
upward, and the odd-numbered pairs move downward. The value –100.00 
represents the maximum movement.
If a positive value is set, the even-numbered pairs of strip and slit move 
downward, and the odd-numbered pairs move upward. The value +100.00 
represents the maximum movement.
Modulation
The pattern signal can be modulated, giving waves on the horizontal or vertical 
edges, or radially. 
The parameter Shape determines the form of the modulation.
1: sine wave, 2: triangular wave, 3: rectangular wave
Note
When using 1080PsF mode in an HD system, the modulation function is not 
available.
Horizontal modulation
This modulates the pattern, applying waviness in the horizontal direction to 
edges.
The parameter Speed determines the speed of waves.
A value of –100.00 generates the maximum downward speed of waves, and a 
value of +100.00 the maximum upward speed.