Soldering with a soldering iron
The use of a soldering iron should be avoided wherever possible. If it is 
unavoidable, follow the instructions set forth in Table 5. The time of soldering with  an iron
should be one.
Table 5
Cleaning after Mounting
The following solvents are usable when cleaning the capacitors after mounting. Never use 
a highly active solvent. 
- Halogen organic solvent (HCFC225, etc.)
- Alcoholic solvent (IPA, ethanol, etc.)
- Petroleum solvent, alkali saponifying agent, water, etc.
Circuit board cleaning must be conducted at a temperature of not higher than 50°C and for 
an immersion time of not longer than 30 minutes. When an ultrasonic cleaning method is 
used, cleaning must be conducted at a frequency of 48 kHz or lower, at an vibrator output 
of 0.02 W/cm3, at a temperature of not higher than 40°C, and for a time of 5 minutes or shorter.
NOTE 1: Care must be exercised in cleaning process so that the mounted capacitor will not come 
into contact with any cleaned object or the like or will not get rubbed by a stiff brush or 
the  like. If such precautions are not taken particularly when the ultrasonic cleaning 
method is employed, terminal breakage may occur.
NOTE 2: When performing ultrasonic cleaning under conditions other than stated above, conduct 
adequate advance checkout.
OTHER
For further details, refer to EIAJ RCR-2368, Precautions and Guidelines for Using  Electronic Device 
Tantalum Capacitors.