Panasonic LK-T Relays User Manual

Page of 3
LK-T
1
ds_61113_0004_en_lkt: 091008J
SPECIFICATIONS
SLIM POWER RELAY 
WITH HIGH INRUSH 
CURRENT CAPABILITY 
TV-8 CERTIFIED
LK-T RELAYS
FEATURES
1. High inrush current capability
1) Operating load capability: 
inrush 118 A, steady 8 A
2) UL/C-UL TV-8 approved
2. High insulation resistance
1) Creepage distance and clearances 
between contact and coil: Min. 6 mm 
.236 
inch
 (In compliance with IEC65)
2) Surge withstand voltage between 
contact and coil: 10,000 V or more
3. High noise immunity realized by the 
card separation structure between 
contact and coil
4. Conforms to the various safety 
standards
UL, C-UL, TÜV, and SEMKO approved
25.0
24.0
11.0
.984
.945
.433
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of 
±1.2 × 50μs according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 
μs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 
μs
*
8
The upper operation ambient temperature limit is the maximum temperature that 
can satisfy the coil temperature rise value. Refer to 1. Usage, transport and 
storage conditions in NOTES on page 3.
Characteristics
Arrangement
1 Form A
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Max. 100 m
Ω
Contact material
AgSnO
2
 type
Rating
(resistive load)
Nominal switching 
capacity
5 A 277 V AC
Max. switching power
1,385 V A
Max. switching voltage
277 V AC
Max. switching current
8 A (120V AC)
Min. switching capacity
#1
(Reference value)
100 mA, 5 V DC
Expected life
(min. operations)
Mechanical (at 180 cpm)
10
6
Electrical (at 20 cpm) 
(at rated load)
10
5
Nominal operating power
250 mW
Max. operating speed
20 cpm (at rated load)
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial *
2
 
breakdown 
voltage
Between open 
contacts
1,000 Vrms for 1 min.
Between contact 
and coil
4,000 Vrms for 1 min.
Initial surge voltage between contact 
and coil*
3
10,000 V
Operate time*
4
(at nominal voltage)
Max. 15ms (at 20
°C 
68
°F
)
Release time (without diode)*
4
(at nominal voltage)
Max. 5ms (at 20
°C 
68
°F
)
Temperature rise (at 70
°C)
Max. 35
°C with nominal coil 
voltage and at 5 A contact 
carrying current
(resistance method)
Shock 
resistance
Functional*
5
200 m/s
2
{approx. 20 G}
Destructive*
6
1,000 m/s
2
{approx. 100 G}
Vibration 
resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation, 
transport and storage*
8
(Not freezing and 
condensing at low 
temperature)
Ambient 
temp.
–40
°C to +70°C
–40
°F to +158°F
Humidity
5 to 85% R.H.
Air 
pressure
86 to 106 kPa
Unit weight
Approx. 12 g 
.42 oz
TYPICAL 
APPLICATIONS
• Audio visual equipment
• Flat TVs and audio equipment, etc.
• Office equipment
• Home appliances
ORDERING INFORMATION
Contact arrangement
Protective construction
Coil voltage(DC)
1a: 1 Form A
F: Flux-resistant type
5, 9, 12, 24V
Ex. LKT
1a
F
12V
UL/C-UL, TÜV, SEMKO, TV-8 approved type is standard.
Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs.
 
2. 3 V, 6 V, and 18 V DC types are also available. Please consult us for details.