3com 4510G User Manual

Page of 66
 
6-4 
 
To ensure the normal operation of the switch, you need to contact the local sales agent or service 
engineer as soon as possible when a fixed fan failure occurs. 
 
Configuration System Failure 
After the switch is powered on and the system is normal, the booting information will be displayed on the 
configuration terminal. If the configuration system has any faults, there will not be any screen display at 
the configuration terminal or the displayed characters will be totally illegible.  
Troubleshooting when there is no terminal display 
If there is no output information after the configuration is powered on, please check whether: 
z
 
The power supply is normal 
z
 
The console cable is properly connected 
If no problems are found after the above-mentioned items have been checked, the cause may lie in the 
console cable or the settings of the terminal (such as hyper terminal) parameters. Please perform the 
corresponding check.  
Troubleshooting when the terminal display is illegible 
If there is illegible display at the configuration terminal, the cause might lie in the parameter setting error 
at the terminal (such as HyperTerminal). Verify the following terminal parameter (such as hyper terminal) 
settings: 
z
 
Baud rate: 19,200  
z
 
Data bits: 8  
z
 
Parity: none 
z
 
Stop bits: 1 
z
 
Flow control: none 
z
 
Terminal emulation: VT100.