The OfficeConnect hub has been designed to aid you when 
detecting and solving possible problems with your network. 
These problems are rarely serious, the cause is usually a 
disconnected or damaged cable, or incorrect configuration. 
If this section does not solve your problem, contact your 
supplier for information on what to do next.
Perform these actions first:
Ensure all equipment is powered on.
Power off the hubs, wait about 5 seconds and then 
power on the hubs.
Check the following symptoms and solutions:
Power LED not lit. Check your power adapter connection. 
If there is still no power, you may have a faulty power 
adapter which needs replacing with another OfficeConnect 
power adapter. Do not use any other power adapter 
with the hub.
Alert LED continuously lit. There is either continual 
excessive use of your network (over 80%) or, more likely, a 
10BASE-T port has partitioned due to a loop in your 
network (in which case the corresponding Port Status LED 
will be yellow). Examine your connections and remove the 
loop. Each piece of equipment needs only one connection 
to your OfficeConnect hub.
Port Status LED yellow for a 10BASE-T port. It is likely 
that there is a loop in your network which has caused this 
port to partition. Examine your connections and remove the 
loop. Each piece of equipment needs only one connection 
to your OfficeConnect hub. The LED will change from 
yellow to green, on receiving a valid packet on the port.
Link between two OfficeConnect hubs not working. 
Check your hub connections; follow the information given 
for your hub. With 10BASE-T it is likely an Uplink/Normal 
switch is incorrectly set. With 10BASE-2 it is likely a 
terminator (end piece) is not properly fitted; this would 
cause the Coax Port Status LED to light yellow (partition).
AUI/COAX Port Status LED not lit when external 
transceiver in use.
 Check the AUI cable is correctly 
connected to the hub and to the external transceiver. Ensure 
both slide locks are engaged.
AUI/COAX Port Status LED yellow when the 10BASE-2 
port is not being used.
 The port has partitioned. This is 
correct operation.