3com 4500 PWR 26-PORT User Manual

Page of 466
Logging in Commands
35
When using the 
undo shell
 command, note the following points.
For reasons of security, the 
undo shell
 command can only be used on user 
interfaces other than the AUX user interface.
You cannot use this command on the current user interface.
You are asked to confirm the command.
Example
To disable the terminal service on the VTY user interfaces 0 to 4, enter the 
following from another user interface:
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]user-interface vty 0 4
[4500-ui-vty0-4]undo shell
speed
Syntax
speed speed-value
undo speed
View
User interface view
Parameter
speed-value:
 Specify the transmission rate on the AUX (Console) port in bits per 
second (bps). This can be any of the following values: 300, 600, 1200, 2400, 
4800, 9600, 19200, 38400, 57600, 115200 or 4096000. 
The default rate is 19200 bps.
Description
Use the 
speed
 command to configure the transmission rate on the AUX (Console) 
port. Use the
 undo speed 
command to restore the default rate.
This command can only be performed in AUX user interface view.
Example
To configure the transmission speed on the AUX (Console) port as 9600 b/s, enter 
the following:
<4500>system-view
System View: return to User View with Ctrl+Z.
[4500]user-interface aux 0
[4500-ui-aux0]speed 9600
stopbits
Syntax
stopbits { 1 | 1.5 | 2 }
undo stopbits
View
User interface view