DELL PC7024 User Manual
1460
RMON Commands
Syntax
rmon alarm
number variable interval {delta | absolute} rising-threshold
value [event-number] falling-threshold value [event-number] [owner string]
[startup
direction]
no rmon alarm
number
Syntax Description
Parameter
Description
number
The alarm index. (Range: 1–65535)
variable
A fully qualified SNMP object identifier that resolves to a
particular instance of a MIB object.
interval
The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. (Range: 1–
2147483647)
rising-threshold
value
Rising Threshold value. (Range: -2147483648 – 2147483647)
falling-threshold
value
Falling Threshold value. (Range: -2147483648 – 2147483647)
event-number
The index of the Event that is used when a rising or falling
threshold is crossed. (Range: 1- 65535)
delta
The sampling method for the selected variable and calculating
the value to be compared against the thresholds. If the method
is delta, the selected variable value at the last sample is
subtracted from the current value, and the difference compared
with the thresholds.
absolute
The sampling method for the selected variable and calculating
the value to be compared against the thresholds. If the method
is absolute, the value of the selected variable is compared
directly with the thresholds at the end of the sampling interval.
2CSPC4.XCT-SWUM2XX1.book Page 1460 Monday, October 3, 2011 11:05 AM